X Plan Fibre-reinforced, self-levelling, quick-hardening compound for levelling of substrates also wooden-based, and for preparation of slopes. Layer thickness 2-50 mm.
Coverage:
7 mm variance on floor - 2 sq m, Over 3 mm heating cables - 3.5 sq / m per bag
Characteristics
- self-levelling
- quick-hardening
- abrasive-resistant
- for wooden-based substrates
- for heated floors
- for manual or mechanical application
- for indoor use
- can be walked on after 3-5 hrs
- next works after 6-12 hrs
Use
Mira x-plan is applicable for preparing of even and smooth under-floor layer; it can be applied on concrete substrate, old tile floor, wooden-based substrates, painted surfaces, in apartments, offices, hospitals, schools, supermarkets, stores, etc. Also used for covering of floor heating cables, preparation of sloped floors. Its advantages are versatility and applicability for quick works. Hardened surface can be covered with any type of facing or lining e.g. ceramic tiles, carpet or vinyl lining, parquet, cork etc. Floor with light traffic can be painted, as the final treatment.
Substrate preparation
The substrate must be stable, dry, compact, cleaned of dust, grease, oil etc. Concrete slurry (if any) should be removed, weaker parts of substrate should be removed and then repaired again. Substrate defects shall be repaired with 6950 express. Grease, oil, dirt should be removed with 7110 base cleaner. The entire surface should be clean of dust. A concrete substrate should be primed with Mira 4180 primer thinned with water.
Thinning Ratio:
1 part of 4180 primer and 1-3 parts of water, depending on absorptivity of the substrate. Non-absorptive substrate should be primed with non-diluted 4180 primer and then powdered with x-plan, which must be rubbed into freshly spread 4180 primer. Wooden-based substrate should be primed with non-diluted 4180 primer. Drying time 1-2 hours. Do not leave any puddle. The primer improves adherence, prevents air bubbles and de-watering of mortar. If more than one layer is laid, each layer must be primed.
Technical conditions:
Mixing X-plan should be mixed in proportion: approx. 4,5 litres of water for 25 kg of dry x-plan. Mix for approx. 2 minutes with a slow-rotating mixer or in a pump mixer, then the mortar is ready to use. Mortar for slopes should be mixed in proportion 4 litres of water for 25 kg of dry x-plan
Preparation, Priming, Mixing & Applying X-Plan Self Levelling Compound
 |
Preparation
The condition of the existing floor has a decisive effect on the final strength of the compound. The surface must be firm, cohesive and free from loose particles, dust, dirt, grease, etc. Any cement slurry film and weak spots in the concrete underlay must be cut or ground away. Loose dust is best removed with a vacuum cleaner, whereas grease, oil, etc. on concrete, painted surface or similar should be removed using – e.g. 7110 base cleaner, high pressure flushing or another effective cleaning method. |
 |
Priming
Priming should not be done until the surface is prepared and dry enough that the primer adheres. Porous surfaces must be treated with 1 part 4180 primer thinned with 3 parts water. It must be worked well into the surface with a brush. On impermeable materials such as painted surfaces and ceramic tiles, concentrated 4180 primer must be applied, followed by dry compound powder sprinkled and brushed into wet primer. Wooden floor boards must be primed with concentrated 4180 primer. If x-plan is applied in several layers, primer must be applied to each layer. The min. ambient temperature is 6 C°, the best 10-18 C°. Coverage: 0,1-0,2 litres of 4180 primer/m2. |
 |
Mixing
X-plan should be mixed with approx. 4.5 litres of water per 25 kg x-plan. Mixing is preferably done with an electric mixer or a mixing pump. The mixture must be worked for at least 2 minutes, until it becomes of an even and smooth texture. If the mixture is to be used in building up a fall in the floor, the quantity of water can be reduced to 4 litres per 25 kg x-plan. Less water reduces the working time and the flow capacity of the mix.
X-plan remains workable for approx. 30 minutes in an ambient temperature of 10-18 C°. |
 |
Concrete, Plaster, Light Concrete, Ceramic Tiles, Painted Surfaces
X-plan must be applied immediately after mixing. It levels itself, but if necessary can be smoothed and spread into corners with a smooth spatula. Thickness on concrete, plaster, ceramic tiles, painted surfaces: 2-50 mm. Thickness on light concrete: 5-30 mm. |
 |
Wooden Floors
X-plan must be applied immediately after mixing. On chipboard, plywood and floor boards it can be applied directly onto the primed surface. If a wooden surface that has been treated with x-plan is to be covered with a hard substance, e.g. ceramic tiles - special instructions are necessary. Thickness: 5-50 mm. |
 |
Heated Floors
X-plan is very suitable for building up thin heated floors. Heating cables must be fastened to a non-flammable underlay with hot-melt adhesive. If an inflammable underlay is used, a layer of x-plan 5 mm. thick under the cables or the use of a 20 mm wire rendering mesh is recommended. A mesh is always recommended where x-plan is to be applied to wooden floor boards. The compound must cover the heating cables by min. 5-10 mm depending on the capacity of the cables and the stability of the underlay. |
 |
Building up a Fall
The mix (with reduced water content) must be applied along the wall. It will itself flow towards the floor drain. Prevent the mix from flowing down into the drain by fastening some kind of retainer to the floor, e.g. Mira planstop - self-adhesive foam plastic strips. When the mix has hardened so that it can be walked on with care, the fall can be adjusted and rendered to match the floor drain. |
 |
Finishing
Further surface treatment is possible when the levelling compound has hardened and dried. The drying time will depend on the moisture content of the underlay. Normally, ceramic tiles can be laid after 6-12 hours. At least 12-18 hours should be allowed after a mix has been applied before damp-proofing with 4120 sealer or 4400 Multicoat is applied. When laying vinyl, linoleum etc. follow the suppliers instructions. |
 |
Mira Flow Test
Place the Mira flow tester on a primed and flat surface. Fill the tester to the top with x-plan and then lift the tester so that the measured amount of x-plan is able to flow out freely. When the compound has flowed completely from the tester on it's own accord, measure the diameter to which it spreads. With the correct amount of water added, this diameter must be 135-145 mm. |
Technical specification
Mira x-plan is supplied as a dry product consisting a special cement, sand, bonding agent, plastic, fibre and additives.
Technical data:
Contents: chemical cement, mineral filler, binding media, plastic, fibre and additives
Layer thickness - cement based substrate 2-50 mm
- wooden based substrate 5-50 mm
- above cables for el-heating min. 5-10 mm
Compressive strength Class C 25*
Flexural strength Class F 6*
Bond strength Class B 1,0*
Dry density 1,7 kg/l
pH coefficient 11 – 12
Spreading (flow-test) 135-145 mm
Application time within 30 min.
Light traffic after Approx. 2 hrs.
Ready for covering 6 – 12 hrs.
* According to EN 13813:2002 (E)
Packing: X-plan is packed in 25 kg plastic-strengthened paper bags.
Storage and transportation: Transport and store dry. Storage period: min. 1 year from the production date in unopened bags